TY - GEN
T1 - Effects of hole pitch to diameter ratio p/d of impingement and film hole on laminated cooling effectiveness
AU - Zhou, Weilun
AU - Deng, Qinghua
AU - He, Wei
AU - Feng, Zhenping
N1 - Publisher Copyright:
Copyright © 2017 ASME.
PY - 2017
Y1 - 2017
N2 - The laminated cooling, also known as impingement-effusion cooling, is believed to be a promising gas turbine blade cooling technique. In this paper, conjugate heat transfer analysis was employed to investigate the overall cooling effectiveness and total pressure loss of the laminated cooling configuration. The pitch to film hole diameter ratio P/Df of 3, 4, 5, 6, combined with pitch to impingement hole diameter ratio P/Di of 4, 6, 8, 10, are studied at the coolant mass flux G of 0.5, 1.0, 1.5, 2.0 kg/(sm2bar) respectively. The results show that overall cooling effectiveness of laminated cooling configuration increases with the decreasing of P/Df and the increasing of the coolant mass flux in general. However P/Df smaller than 3 may leads to a serious blocking in first few film holes at low coolant mass flux. The large P/Di that makes the Mach number of impingement flow greater than 0.16 may cause unacceptable pressure loss. The increment of overall cooling effectiveness depends on the difference between the deterioration of external cooling and the enhancement of internal cooling. Pressure loss increases exponentially with P/Di and G, and it increases more slowly with P/Df that compared to P/Di and G. The mixing loss takes up the most pressure loss at low coolant mass flux. With the increasing of the whole pressure loss, the proportion of throttling loss and laminated loss becomes larger and finally takes up the most of the whole pressure loss. When the sum of throttling loss and laminated loss is greater than mixing loss, the increment of system pressure ratio is unreasonable that compared to the increment of overall cooling effectiveness.
AB - The laminated cooling, also known as impingement-effusion cooling, is believed to be a promising gas turbine blade cooling technique. In this paper, conjugate heat transfer analysis was employed to investigate the overall cooling effectiveness and total pressure loss of the laminated cooling configuration. The pitch to film hole diameter ratio P/Df of 3, 4, 5, 6, combined with pitch to impingement hole diameter ratio P/Di of 4, 6, 8, 10, are studied at the coolant mass flux G of 0.5, 1.0, 1.5, 2.0 kg/(sm2bar) respectively. The results show that overall cooling effectiveness of laminated cooling configuration increases with the decreasing of P/Df and the increasing of the coolant mass flux in general. However P/Df smaller than 3 may leads to a serious blocking in first few film holes at low coolant mass flux. The large P/Di that makes the Mach number of impingement flow greater than 0.16 may cause unacceptable pressure loss. The increment of overall cooling effectiveness depends on the difference between the deterioration of external cooling and the enhancement of internal cooling. Pressure loss increases exponentially with P/Di and G, and it increases more slowly with P/Df that compared to P/Di and G. The mixing loss takes up the most pressure loss at low coolant mass flux. With the increasing of the whole pressure loss, the proportion of throttling loss and laminated loss becomes larger and finally takes up the most of the whole pressure loss. When the sum of throttling loss and laminated loss is greater than mixing loss, the increment of system pressure ratio is unreasonable that compared to the increment of overall cooling effectiveness.
KW - Conjugate heat transfer
KW - Hole pitch to diameter ratio
KW - Laminated cooling
KW - Overall cooling effectiveness
KW - Pressure loss
UR - https://www.scopus.com/pages/publications/85029091811
U2 - 10.1115/GT2017-64566
DO - 10.1115/GT2017-64566
M3 - 会议稿件
AN - SCOPUS:85029091811
T3 - Proceedings of the ASME Turbo Expo
BT - Heat Transfer
PB - American Society of Mechanical Engineers (ASME)
T2 - ASME Turbo Expo 2017: Turbomachinery Technical Conference and Exposition, GT 2017
Y2 - 26 June 2017 through 30 June 2017
ER -