Abstract
A few CT-based voxel phantoms were produced to investigate the sensitivity of Monte Carlo simulations of X-ray beam and electron beam to the proportions of elements an the mass densities of the materials used to express the patient's anatomical structure. The human body can be well outlined by air, lung, adipose, muscle, soft bone and hard bone to calculate the dose distribution with Monte Carlo method. The effects of the calibration curves established by using various CT scanners are not clinically significant based on our investigation. The deviation from the values of cumulative dose volume histogram derived from CT-based voxel phantoms is less than 1% for the given target.
| Original language | English |
|---|---|
| Pages (from-to) | 2777-2780 |
| Number of pages | 4 |
| Journal | Plasma Science and Technology |
| Volume | 7 |
| Issue number | 2 |
| DOIs | |
| State | Published - Apr 2005 |
Keywords
- Calibration curve
- CT voxel phantom
- Dose calculation
- Monte Carlo
Fingerprint
Dive into the research topics of 'Effects of CT based voxel phantoms on dose distribution calculated with Monte Carlo method'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS