Skip to main navigation Skip to search Skip to main content

Economic diagnostic method of thermal system with outer steam cooler

  • X. Y. Li
  • , J. J. Yan
  • , C. Y. Zhang
  • , W. C. Lin
  • , J. P. Sui
  • Xi'an Jiaotong University

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

Based on the strict theoretical and mathematical analyses, a general function for calculating the equivalent enthalpy drops of steam power unit with outer steam cooler was developed and an economic diagnostic method was set up. The mathematical models for the part thermal system with double outer steam coolers and the mathematical models for the part thermal system with parallel connection of outer steam cooler were given. The temperature of feedwater can be raised due to the use of outer steam cooler. According to the calculating results of practical examples, the method is proved to be simple, accurate and valuable for application.

Original languageEnglish
Pages (from-to)35-39
Number of pages5
JournalZhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering
Volume21
Issue number1
StatePublished - Jan 2001

Keywords

  • Economy
  • Outer steam cooler
  • Quantitative analysis
  • Thermal system

Fingerprint

Dive into the research topics of 'Economic diagnostic method of thermal system with outer steam cooler'. Together they form a unique fingerprint.

Cite this