Abstract
A study of the dryout characteristics in forced convection boiling in electrically heated horizontal helically coiled tube is reported. The results demonstrate that dryout usually occurs at the front (θ=90°) and back side (θ=270°) of the exit cross-section. The secondary flow induced by centrifugal force and the wall heat conduction around the dryout points are the dominant mechanisms of dryout in a helically coiled tube. Based on the experimental data, a correlation for predicting the critical dryout quality of horizontal helically coiled tube is proposed.
| Original language | English |
|---|---|
| Pages (from-to) | 180-185 |
| Number of pages | 6 |
| Journal | Huagong Xuebao/Journal of Chemical Industry and Engineering (China) |
| Volume | 48 |
| Issue number | 2 |
| State | Published - Apr 1997 |