Skip to main navigation Skip to search Skip to main content

Dielectric relaxation and carrier transport in epoxy resin

  • Shengjun Lin
  • , Yin Huang
  • , Dongri Xie
  • , Zhen Li
  • , Daomin Min
  • , Shihu Yu
  • , Shengtao Li
  • Pinggao Group Co. Ltd.
  • Xi'an Jiaotong University

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

1 Scopus citations

Abstract

Epoxy resin (EP) is widely used as an insulating material in power equipment. Its dielectric relaxation and carrier transport properties are important factors affecting breakdown and surface flashover performance. The dielectric relaxation and carrier transport properties of EP based alumina (Al2O3) microcomposite were investigated through broadband dielectric spectroscopy. The glass transition temperature was measured by differential scanning calorimetry (DSC), which is about 120 °C. Gold electrodes with a diameter of 30 mm were sputtering on two sides of the samples. A broadband dielectric spectrometer (Concept 80 Novocontrol) was used to measure the dielectric relaxation properties at an ac voltage of 1 Vrms in a frequency range from 10-1 to 107 Hz at various temperatures. Above the glass transition temperature, a relaxation peak occurs at high frequencies due to the motion of molecular chains or segmental chains, and a dc conductivity resulted by the migration of charge carriers appears at low frequencies. In addition, molecular chains with different scales have different relaxation times. It was found that EP microcomposite has a very broad distribution of relaxation time. We calculated the distribution of relaxation time at various temperatures. Furthermore, the temperature dependences of molecular relaxation and dc conductivity satisfy the Vogel-Tammann-Fulcher equation. Fitting the experimental results, we obtained the Vogel temperatures and strength parameters of molecular relaxation and dc conductivity. From the Vogel temperatures, we estimated the glass transition temperature to be 117 °C, which is consistent with the DSC result. It means that free volume increases with increasing temperature, facilitating the motion of molecular chains and the migration of charge carriers.

Original languageEnglish
Title of host publicationProceedings of the 2016 IEEE International Conference on Dielectrics, ICD 2016
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages1167-1170
Number of pages4
ISBN (Electronic)9781509028023
DOIs
StatePublished - 18 Aug 2016
Event1st IEEE International Conference on Dielectrics, ICD 2016 - Montpellier, France
Duration: 3 Jul 20167 Jul 2016

Publication series

NameProceedings of the 2016 IEEE International Conference on Dielectrics, ICD 2016
Volume2

Conference

Conference1st IEEE International Conference on Dielectrics, ICD 2016
Country/TerritoryFrance
CityMontpellier
Period3/07/167/07/16

Keywords

  • Vogel-Fulcher-Tamman equation
  • carrier transport
  • dielectric relaxation
  • epoxy resin microcomposite
  • glass transtion

Fingerprint

Dive into the research topics of 'Dielectric relaxation and carrier transport in epoxy resin'. Together they form a unique fingerprint.

Cite this