Skip to main navigation Skip to search Skip to main content

Development of a transient thermal-hydraulic analysis code for China advanced research reactor

  • Xi'an Jiaotong University
  • China National Nuclear Corporation

Research output: Contribution to journalArticlepeer-review

2 Scopus citations

Abstract

A transient analysis code was developed to calculate the thermal-hydraulic behaviors of China advanced research reactor (CARR). The detailed structure of CARR and the fluid flow direction inverse during the process of natural circulation establishment were considered. Moreover, the flow patterns and heat transfer conditions were taking into account. In addition, Gear method and Adams predictor-corrector method were adopted separately for a better solution to the stiff differential equations. Some important parameters such as pressure, flow rate and temperature for the mean channel and hot channel were obtained. Our research result show that the used of emergency cooling system obviously reduced the peak operational temperature to ensure the safe operation of CARR more effectively.

Original languageEnglish
Pages (from-to)308-312
Number of pages5
JournalHsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University
Volume39
Issue number3
StatePublished - Mar 2005

Keywords

  • China advanced research reactor
  • Flow inversion
  • Natural convection
  • Safety analysis
  • Transient analysis

Fingerprint

Dive into the research topics of 'Development of a transient thermal-hydraulic analysis code for China advanced research reactor'. Together they form a unique fingerprint.

Cite this