Abstract

Ex-Vessel Neutron Dosimetry (EVND) systems had been used worldwide in nuclear power industry because of its easier implementation, higher reliability and lower cost compared to in-vessel surveillance capsules. EVND system measures reactor pressure vessel (RPV) neutron fluence and neutron spectrum with multiple activation foils installed outside of RPV. A special EVND system was designed and manufactured for Tianwan Nuclear Power Plant VVER-1000 reactor units in China, based on the characters of their fuel scheme, reactor internals, RPV and also the components and structures outside of RPV. The EVND system was composed of six dosimeter sets which were installed in six different locations. Each dosimeter set had eight foils. Stainless steel chain which was used to support the dosimeter sets also provided useful information to describe the axial distribution of reactor neutron fluence. The system was installed during the 11th refueling outage and was with-drawn after one fuel cycle. Then the activated foils were measured and analyzed to obtain the reaction rates of target nuclides. Neutron transport calculation was carried out to obtain neutron fluence and neutron spectrum distribution. Spectrum adjust-ment calculation was carried out to obtain best estimated neutron fluence based on dosimeter measurement results. Calculated, best estimated and measured reaction rates were compared for each foil. Also, calculated and best estimated neutron spec-trums at each dosimeter set location were compared. Finally, correctness of RPV fast neutron fluence and spectrum was assessed based on these comparisons. The results showed that the calculated, measured and best estimated reaction rates of most dosimeters complied with each other very well. It can be concluded that the EVND system can provide accurate RPV neutron fluence for Tianwan VVER-1000 reactor units.

Original languageEnglish
Title of host publicationProceedings of the 32nd International Conference on Nuclear Engineering—Volume 1; ICONE 2025
EditorsSichao Tan, Weiqiang Xu, Yanyan Zhu
PublisherSpringer Science and Business Media Deutschland GmbH
Pages171-182
Number of pages12
ISBN (Print)9789819527939
DOIs
StatePublished - 2026
Event32nd International Conference on Nuclear Engineering, ICONE 2025 - Weihai, China
Duration: 22 Jun 2025 → 26 Jun 2025

Publication series

NameSpringer Proceedings in Physics
Volume330 SPPHY
ISSN (Print)0930-8989
ISSN (Electronic)1867-4941

Conference

Conference32nd International Conference on Nuclear Engineering, ICONE 2025
Country/TerritoryChina
CityWeihai
Period22/06/25 → 26/06/25

Keywords

  • Ex-vessel neutron dosimetry system
  • Neutron fluence
  • Reactor vessel
  • Spectrum adjustment
  • VVER-1000 reactor