Determination of secnidazole in human plasma by high-performace liquid chromatography with UV detection and its application to the bioequivalence studies

  • Xiaoyu Li
  • , Jianguo Sun
  • , Guangji Wang
  • , Yuanting Zheng
  • , Bei Yan
  • , Haitang Xie
  • , Yi Gu
  • , Hongchan Ren

Research output: Contribution to journalArticlepeer-review

15 Scopus citations

Abstract

A simple, accurate, precise and sensitive HPLC-UV method was developed for the determination of secnidazole in human plasma. Secnidazole and tinidazole (IS) were extracted from 0.2 mL of human plasma by ethyl acetate. Secnidazole was then separated by HPLC on a Diamond C18 column and quantified by ultraviolet detection at 319 nm. The mobile phase consisted of acetonitrile-aqueous 5 mM sodium acetate (30:70, v/v) containing of 0.1% acetic acid adjusted to pH 4.0, and the flow rate was 1.0 mL/min. The low limit of quantification was 0.1 μg/mL. The method was linear over the concentration range 0.1-25.0 μg/mL (R2 = 1.000). The recovery of secnidazole from human plasma ranged from 76.5 to 89.1%. Inter- and intra-assay precision ranged from 3.3 to 10.7%. Secnidazole in plasma was stable when stored at ambient temperature for 8 h, at -20°C for 2 weeks and at -20°C for three freeze-thaw cycles. The developed method was successfully applied to the pharmacokinetic and bioequivalence studies between test and reference secnidazole tablets following a single 500 mg oral dosage to 20 healthy volunteers of both genders. Pharmacokinetics parameters Tmax, Cmax, AUC0-t, AUC0-∞, T1/2 were determined of both preparations. The analysis of variance (ANOVA) did not show any significant difference between the two preparations and 90% confidence intervals fell within the acceptable range for bioequivalence. It was concluded that the two secnidazole preparations are bioequivalence and may be used interchangeably.

Original languageEnglish
Pages (from-to)304-309
Number of pages6
JournalBiomedical Chromatography
Volume21
Issue number3
DOIs
StatePublished - Mar 2007
Externally publishedYes

Keywords

  • Bioequivalence study
  • HPLC
  • Pharmacokinetics
  • Secnidazole
  • Tinidazole

Fingerprint

Dive into the research topics of 'Determination of secnidazole in human plasma by high-performace liquid chromatography with UV detection and its application to the bioequivalence studies'. Together they form a unique fingerprint.

Cite this