Skip to main navigation Skip to search Skip to main content

Determination of boron in industrial waste water by low pressure ion exclusion chromatography

  • Xin Feng Xiao
  • , Xin Shen Zhang
  • , Ya Jun Luo
  • , Guo He Chen
  • , Zheng Jun Gong
  • Sichuan University
  • Shandong University of Science and Technology
  • Mianyang Normal University

Research output: Contribution to journalArticlepeer-review

Abstract

A new method for the determination of boron by low pressure strong acid cation-exchange exclusion chromatography and the conductivity detector was proposed. The chromatographic column was filled with strong acid cation-exchange resin with improved granularity and degree of sulfonic, and mannitol-nitric acid-water was used as eluent. The method needn't a suppressor column, and the chromatographic conditions of separation and detection were modified. The detection limit was 5.0 × 10-5 mol/L, and the linear range was 0.2 × 10-3 - 5.0 × 10-3 mol/L for boron, with RSD = 2.0% (n = 11). The method was applied to the determination of boron in industrial waste water with satisfactory results.

Original languageEnglish
Pages (from-to)59-62
Number of pages4
JournalSichuan Daxue Xuebao (Gongcheng Kexue Ban)/Journal of Sichuan University (Engineering Science Edition)
Volume38
Issue number1
StatePublished - Jan 2006
Externally publishedYes

Keywords

  • Boron
  • Industrial waste water
  • Low pressure ion chromatography
  • Retention behavior

Fingerprint

Dive into the research topics of 'Determination of boron in industrial waste water by low pressure ion exclusion chromatography'. Together they form a unique fingerprint.