TY - JOUR
T1 - Determination of 2-undecanone in Chinese medicine Houttuynia cordata thunb by HPLC-CL detection
AU - Li, Weifeng
AU - Yu, Hongling
AU - Niu, Xiaofeng
AU - Tang, Yuhai
AU - He, Langchong
PY - 2011/1
Y1 - 2011/1
N2 - A simple, sensitive, and accurate HPLC-CL method was developed for the first time to determine 2-undecanone in the dried aerial parts of Houttuynia cordata Thunb (HC), which has been widely used as one of the more common traditional Chinese medicines (TCMs). This HPLC-CL assay was performed on a reversed-phase C18 column (250mm×4.6mm, 5m) at the column temperature of 35°C. The mobile phase was composed of acetonitrile and water (50:50, v/v). The flow rate was 1.0mL/min. The chemiluminescence was produced by luminol oxidation during a reactor of which was based on the analytes enhancement effect on the CL reaction between luminol and K3Fe(CN)6. The calibration curves showed good linear regression (r2=0.9993) within the test range of 3.0×10 -8-1.0×10 -5g/mL. The established method showed good precision with average intra-day and inter-day variations of 2.08% and 1.85%, respectively, and a recovery of 99.55% for the 2-undecanone. The validated method was successfully applied for the determination of 2-undecanone in 9 samples from 9 different cultivation regions. The present HPLC-CL method was demonstrated to be very helpful in the quantification of 2-undecanone in HC.
AB - A simple, sensitive, and accurate HPLC-CL method was developed for the first time to determine 2-undecanone in the dried aerial parts of Houttuynia cordata Thunb (HC), which has been widely used as one of the more common traditional Chinese medicines (TCMs). This HPLC-CL assay was performed on a reversed-phase C18 column (250mm×4.6mm, 5m) at the column temperature of 35°C. The mobile phase was composed of acetonitrile and water (50:50, v/v). The flow rate was 1.0mL/min. The chemiluminescence was produced by luminol oxidation during a reactor of which was based on the analytes enhancement effect on the CL reaction between luminol and K3Fe(CN)6. The calibration curves showed good linear regression (r2=0.9993) within the test range of 3.0×10 -8-1.0×10 -5g/mL. The established method showed good precision with average intra-day and inter-day variations of 2.08% and 1.85%, respectively, and a recovery of 99.55% for the 2-undecanone. The validated method was successfully applied for the determination of 2-undecanone in 9 samples from 9 different cultivation regions. The present HPLC-CL method was demonstrated to be very helpful in the quantification of 2-undecanone in HC.
KW - 2-undecanone
KW - chemiluminescence
KW - high performance liquid chromatography
KW - Houttuynia cordata Thunb
UR - https://www.scopus.com/pages/publications/80052331559
U2 - 10.1080/10826076.2011.575974
DO - 10.1080/10826076.2011.575974
M3 - 文章
AN - SCOPUS:80052331559
SN - 1082-6076
VL - 34
SP - 1431
EP - 1441
JO - Journal of Liquid Chromatography and Related Technologies
JF - Journal of Liquid Chromatography and Related Technologies
IS - 14
ER -