Abstract
A indirect detection method for energy flux density distribution of fresnel lens focal spot in concentration photovoltaic system was proposed, an experimental apparatus for detection was built. The specific process of extracting the spot energy flow density distribution from fresnel lens focal spot gray scale image was introduced in detail after the scaling factor k between the pixel gray values of the camera and the flux density was demarcated. The detection precision of this method was verified. The results indicat that, the relative error of peak value energy flow density detected by this method is less than 2.1%. This method has advantages of easy operation and high accuracy which can been widely applied in detecting for energy flux density distribution of fresnel lens focal spot in concentration photovoltaic system.
| Original language | English |
|---|---|
| Pages (from-to) | 902-905 |
| Number of pages | 4 |
| Journal | Bandaoti Guangdian/Semiconductor Optoelectronics |
| Volume | 37 |
| Issue number | 6 |
| DOIs | |
| State | Published - 1 Dec 2016 |
| Externally published | Yes |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Detection
- Energy flux density distribution
- Focal spot
- Fresnel lens
- Gray scale image
Fingerprint
Dive into the research topics of 'Detection method for energy flux density distribution of fresnel lens focal spot'. Together they form a unique fingerprint.Cite this