A novel flexure hinge, Right-Circular Corner-Filleted (RCCF) flexure hinge is presented for beam line of synchrotron radiation. The performance of RCCF hinge was analyzed and verified by experiments. The results show that the RCCF hinges are more compliant than right-circular hinge and as precise as it in rotation. When required maximum rotation angle is defined, it could cut down the driving capability of actuator and reduce the stress in the device by adopting RCCF hinge.
| Original language | English |
|---|---|
| Pages (from-to) | 119-122 |
| Number of pages | 4 |
| Journal | Guangdian Gongcheng/Opto-Electronic Engineering |
| Volume | 33 |
| Issue number | 3 |
| State | Published - Mar 2006 |
| Externally published | Yes |
Keywords
- Beam line
- Finite element analysis
- Flexure hinge
- Synchrotron radiation
Fingerprint