T1 - Design and characterization of a lab-on-chip for continuous bioluminescent measurements of ATP
AU - Feng, Shilun
AU - Dong, Tao
PY - 2014
Y1 - 2014
N2 - A novel multifunctional two-sides silicon lab-on-chip (LOC) was designed and fabricated for providing a high-efficient long-term continuous analysis platform of measuring the concentration of adenosine 5'-triphosphate (ATP) based on bioluminescence. This lab-on-chip mainly consists of Y shape internal ribbed micro mixers, T-junction droplet generators, different kinds of spiral time delay channels (TD-Cs) and the chambers. Enzyme solutions and ATP were separately injected into the chip at different flow rates through 3 inlet ports. Due to the advantage of Segmented Flow Analysis (SFA), it was introduced and applied with the T-junction droplet generators in this paper, and thus oxygen was injected into the central of the bottom surface through another main inlet periodically. Numerical investigations prove that combing with SFA and T-junction droplet generator is stable to transport the sample; micro mixer can achieve an outstanding mixing efficiency in a small space; the detection of ATP standard solution at optimal conditions was successful, keeping a good linearity between the concentration with the intensity of light during the range from 10-5 mol /ml to 10-9 mol/ml.
AB - A novel multifunctional two-sides silicon lab-on-chip (LOC) was designed and fabricated for providing a high-efficient long-term continuous analysis platform of measuring the concentration of adenosine 5'-triphosphate (ATP) based on bioluminescence. This lab-on-chip mainly consists of Y shape internal ribbed micro mixers, T-junction droplet generators, different kinds of spiral time delay channels (TD-Cs) and the chambers. Enzyme solutions and ATP were separately injected into the chip at different flow rates through 3 inlet ports. Due to the advantage of Segmented Flow Analysis (SFA), it was introduced and applied with the T-junction droplet generators in this paper, and thus oxygen was injected into the central of the bottom surface through another main inlet periodically. Numerical investigations prove that combing with SFA and T-junction droplet generator is stable to transport the sample; micro mixer can achieve an outstanding mixing efficiency in a small space; the detection of ATP standard solution at optimal conditions was successful, keeping a good linearity between the concentration with the intensity of light during the range from 10-5 mol /ml to 10-9 mol/ml.
KW - Adenosine 5'-triphosphate (ATP)
KW - Internal ribbed micro mixer
KW - Lab-on-chip
KW - T-junction droplet generator
UR - https://www.scopus.com/pages/publications/84906902032
U2 - 10.1109/MeMeA.2014.6860076
DO - 10.1109/MeMeA.2014.6860076
M3 - 会议稿件
AN - SCOPUS:84906902032
SN - 9781479929207
T3 - IEEE MeMeA 2014 - IEEE International Symposium on Medical Measurements and Applications, Proceedings
BT - IEEE MeMeA 2014 - IEEE International Symposium on Medical Measurements and Applications, Proceedings
PB - IEEE Computer Society
T2 - 9th IEEE International Symposium on Medical Measurements and Applications, IEEE MeMeA 2014
Y2 - 11 June 2014 through 12 June 2014
ER -