TY - JOUR
T1 - Design and analysis of a combined strain-vibration-temperature sensor with two fiber bragg gratings and a trapezoidal beam.
AU - Yao, Kun
AU - Lin, Qijing
AU - Jiang, Zhuangde
AU - Zhao, Na
AU - Peng, Gang Ding
AU - Tian, Bian
AU - Jia, Wenyun
AU - Yang, Ping
N1 - Publisher Copyright:
© 2019 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2019/8/2
Y1 - 2019/8/2
N2 - A combined sensor to simultaneously measure strain, vibration, and temperature has been developed. The sensor is composed of two Fiber Bragg gratings (FBGs) and a vibration gainer. One FBG is used to measure strain, while the other measures vibration and temperature. The gainer has a mass block which is used to increase its sensitivity to vibration. The main beam of the vibration gainer was designed as a trapezoid in order to reduce the strain gradient while sensing vibration. In addition, an interrogation method was used to eliminate interactions between measured parameters. Experiments were carried out to analyze the performance of the proposed sensor. For individual strain measurement in the range of 0-152 με, the sensitivity and nonlinearity error were 1.878 pm/με and 2.43% Full Scale (F.S.), respectively. For individual temperature measurement in the range of 50-210 °C, the sensitivity and nonlinearity error were 29.324 pm/°C and 1.88% F.S., respectively. The proposed sensor also demonstrated a sensitivity of 0.769 pm/m·s-2 and nonlinearity error of 1.83% F.S. for vibration measurement in the range of 10-55 m/s2. Finally, simultaneously measuring strain, temperature, and vibration resulted in nonlinearity errors of 4.23% F.S., 1.89% F.S., and 2.23% F.S., respectively.
AB - A combined sensor to simultaneously measure strain, vibration, and temperature has been developed. The sensor is composed of two Fiber Bragg gratings (FBGs) and a vibration gainer. One FBG is used to measure strain, while the other measures vibration and temperature. The gainer has a mass block which is used to increase its sensitivity to vibration. The main beam of the vibration gainer was designed as a trapezoid in order to reduce the strain gradient while sensing vibration. In addition, an interrogation method was used to eliminate interactions between measured parameters. Experiments were carried out to analyze the performance of the proposed sensor. For individual strain measurement in the range of 0-152 με, the sensitivity and nonlinearity error were 1.878 pm/με and 2.43% Full Scale (F.S.), respectively. For individual temperature measurement in the range of 50-210 °C, the sensitivity and nonlinearity error were 29.324 pm/°C and 1.88% F.S., respectively. The proposed sensor also demonstrated a sensitivity of 0.769 pm/m·s-2 and nonlinearity error of 1.83% F.S. for vibration measurement in the range of 10-55 m/s2. Finally, simultaneously measuring strain, temperature, and vibration resulted in nonlinearity errors of 4.23% F.S., 1.89% F.S., and 2.23% F.S., respectively.
KW - Combined FBG sensor
KW - Simultaneously sensing
KW - Strain sensing
KW - Temperature sensing
KW - Trapezoidal beam
KW - Vibration sensing
UR - https://www.scopus.com/pages/publications/85071546234
U2 - 10.3390/s19163571
DO - 10.3390/s19163571
M3 - 文章
C2 - 31426308
AN - SCOPUS:85071546234
SN - 1424-8220
VL - 19
JO - Sensors (Switzerland)
JF - Sensors (Switzerland)
IS - 16
M1 - 3571
ER -