Skip to main navigation Skip to search Skip to main content

Critical parameters in design of active magnetocaloric regenerators for magnetic refrigeration applications

  • Xi'an Jiaotong University

Research output: Contribution to journalArticlepeer-review

18 Scopus citations

Abstract

A new way to evaluate the performance of the active magnetocaloric regenerator (AMR) was developed based on a few critical parameters proposed in this study. The critical parameters were derived from the energy equations that have been used to describe the transient energy transfer processes in the AMR for both the magnetocaloric materials and the heat transfer fluid. Each parameter is corresponding to a specific energy transfer mechanism in the AMR and can be easily implemented to evaluate the contribution from each term, including axial conduction and remnant energy storage in the magnetocaloric materials, axial conduction, remnant energy storage and fluid dissipation in the heat transfer fluid, and internally regenerated energy. Parametric studies were carried out to explore the impact of geometric and operating parameters and to determine whether or not a certain heat transfer mechanism is significant to the overall system performance.

Original languageEnglish
Pages (from-to)151-164
Number of pages14
JournalInternational Journal of Refrigeration
Volume84
DOIs
StatePublished - Dec 2017

Keywords

  • Gadolinium
  • Magnetocaloric cooling
  • Magnetocaloric effect
  • Simulation
  • Solid-state cooling

Fingerprint

Dive into the research topics of 'Critical parameters in design of active magnetocaloric regenerators for magnetic refrigeration applications'. Together they form a unique fingerprint.

Cite this