Skip to main navigation Skip to search Skip to main content

Count Rate Analysis of the Source-range Detector for M310

  • Xi'an Jiaotong University
  • Ltd

Research output: Contribution to journalConference articlepeer-review

Abstract

This paper analyses the count rate of the ex-core source-range detector for Unit 4, M310 Pressurized Water Reactor (PWR), at Fujian Fuqing Nuclear Power Co., Ltd (FQNPC). The analysis encompasses power states during Cycle 1 startup and Cycle 3 fuel unloading. The analytical process involves analysing the count rate of the source-range detector, simulating secondary neutron source intensity and calculating nuclide information and neutron source intensity of irradiated fuel assemblies, etc. The maximum error between the theoretically calculated and measured count rate of the source-range detector is found to be 8.318%, which confirms the accuracy and validity of the count rate analysis method applied to the ex-core source-range detector for M310.

Original languageEnglish
Article number14001
JournalEPJ Web of Conferences
Volume302
DOIs
StatePublished - 15 Oct 2024
Event2024 Joint International Conference on Supercomputing in Nuclear Applications + Monte Carlo, SNA + MC 2024 - Paris, France
Duration: 20 Oct 202424 Oct 2024

Fingerprint

Dive into the research topics of 'Count Rate Analysis of the Source-range Detector for M310'. Together they form a unique fingerprint.

Cite this