Skip to main navigation Skip to search Skip to main content

Corrosion-resistant and bioactive FeMn-CaP-Col@CS coating on magnesium alloy for orthopedic implants: Fabrication and characterization

  • Xuhui Liu
  • , Zijin Xiao
  • , Yang Yuan
  • , Qihong Huang
  • , Kaiwei Tang
  • , Yilong Dai
  • , Dechuang Zhang
  • , Jia She
  • , Feng Peng
  • , Fugang Qi
  • , Xiaoping Ouyang
  • XiangTan University
  • The Affiliated Hospital of Hangzhou Normal University
  • Chongqing University
  • Guangdong Academy of Medical Sciences

Research output: Contribution to journalArticlepeer-review

2 Scopus citations

Abstract

To address the rapid degradation behavior of magnesium alloys in physiological environments, a multifunctional gradient FeMn-CaP-Col@CS composite coating was fabricated on the surface of biodegradable WE43 magnesium alloy. The FeMn alloy interlayer was deposited via filtered cathodic vacuum arc (FCVA) technology, with optimized substrate bias voltage and deposition parameters to improve corrosion resistance and mechanical performance. Subsequently, a calcium phosphate (CaP) layer and a bioactive polymer layer composed of collagen (Col) and chitosan (CS) were sequentially introduced via chemical conversion treatment to construct a compact, uniform multilayer coating. The sample with FeMn-CaP-Col@CS composite coating exhibited a significantly reduced corrosion current density compared to uncoated WE43, along with a markedly increased impedance. Biological evaluations, including cytocompatibility assays and live/dead cell staining, indicated excellent cell viability and adhesion on the coated samples. Real-time quantitative polymerase chain reaction (RT-qPCR) analysis revealed upregulated expression of osteogenesis-related genes. The composite coating effectively maintained a favorable microenvironment while providing moderate osteoinductivity due to the synergistic effect of Col and CS. In summary, the FeMn-CaP-Col@CS gradient coating system substantially enhances the corrosion resistance and biocompatibility of WE43 magnesium alloy, offering a promising strategy for the clinical application of magnesium-based orthopedic implants.

Original languageEnglish
Pages (from-to)1-12
Number of pages12
JournalMetals Advances
Volume39
DOIs
StatePublished - Jan 2026
Externally publishedYes

Keywords

  • Composite coating
  • Corrosion
  • Magnesium
  • Osteogenesis

Fingerprint

Dive into the research topics of 'Corrosion-resistant and bioactive FeMn-CaP-Col@CS coating on magnesium alloy for orthopedic implants: Fabrication and characterization'. Together they form a unique fingerprint.

Cite this