Control strategies and dynamic experimental tests on the wide-range and rapid load regulation of a first pilot multi-megawatts fossil-fired supercritical CO2 power system

  • Hongzhi Li
  • , Yifan Zhang
  • , Wengang Bai
  • , Yu Yang
  • , Kailun Li
  • , Wei Gao
  • , Lei Zhang
  • , Chun Zhang
  • , Shuaishuai Wu
  • , Xuwei Zhang
  • , Yongqiang Qiao
  • , Yujia Zhou
  • , Jiarong Wu
  • Thermal Power Research Institute
  • National Engineering Research Center of Integration and Maintenance of Clean and Low-carbon Thermal Power Generation System

Research output: Contribution to journalArticlepeer-review

74 Scopus citations

Abstract

Supercritical CO2 (sCO2) power system is a research front in recent years due to its high efficiency and flexibility which is considered as a transformative power system in terms of consumption of the fluctuated and intermittent renewables. The merits of sCO2 power systems have been widely shown by small-scale test loops. However, it is still very lack of the investigations on the control strategies based on real-time dynamic operational data of large-scale multi-megawatts pilot power system, especially for wide-range and rapid load regulation to demonstrate the feasibility of large-scale utilization and commercialization. A worldwide first pilot multi-megawatts SMART (Supercritical CO2 Modular Advanced Research and Test) fossil-fired power system has been built and operated for more than 1000 h at TPRI (Thermal Power Research Institute), Xi'an, China with turbine inlet parameters of 20 MPa/600 °C/600 °C. The influence of key parameters on the dynamics of the system are experimental studied. In-depth tests of the wide-range load regulation and rapid load regulation of the SMART@TPRI power system are performed. The test results show that the key target parameters such as turbine inlet temperatures, compressor inlet temperature and pressure, sCO2 mass flow rate and exhaust flue gas temperature can be well regulated by a set of well-developed control modules to ensure an efficient and safe operation during load variations. The SMART@TPRI power system can run stably and flexibly within the whole range from 0 %Pe to 100 %Pe. The averaged load ramp and load reduction rate achieves 6.35 %Pe/min and −6.37 %Pe/min, respectively, which is almost 3 ∼ 4 times than that of steam power system, under the control strategy of sliding pressure with fixed turbine inlet temperature by a combination of several novel well-developed control modules.

Original languageEnglish
Article number116748
JournalEnergy Conversion and Management
Volume279
DOIs
StatePublished - 1 Mar 2023
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • Control strategy
  • Dynamic characteristic
  • Load regulation
  • Pilot system
  • Supercritical CO power cycle

Fingerprint

Dive into the research topics of 'Control strategies and dynamic experimental tests on the wide-range and rapid load regulation of a first pilot multi-megawatts fossil-fired supercritical CO2 power system'. Together they form a unique fingerprint.

Cite this