Skip to main navigation Skip to search Skip to main content

Contribution of geometric design parameters to knee implant performance: Conflicting impact of conformity on kinematics and contact mechanics

  • Xi'an Jiaotong University
  • University of Hull
  • University of Leeds

Research output: Contribution to journal › Article › peer-review

36 Scopus citations

Abstract

Background: Articular geometry of knee implant has a competing impact on kinematics and contact mechanics of total knee arthroplasty (TKA) such that geometry with lower contact pressure will impose more constraints on knee kinematics. The geometric parameters that may cause this competing effect have not been well understood. This study aimed to quantify the underlying relationships between implant geometry as input and its performance metrics as output. Methods: Parametric dimensions of a fixed-bearing cruciate retaining implant were randomized to generate a number of perturbed implant geometries. Performance metrics (i.e., maximum contact pressure, anterior-posterior range of motion [A-P ROM] and internal-external range of motion [I-E ROM]) of each randomized design were calculated using finite element analysis. The relative contributions of individual geometric variables to the performance metrics were then determined in terms of sensitivity indices (SI). Results: The femoral and tibial distal or posterior radii and femoral frontal radius are the key parameters. In the sagittal plane, distal curvature of the femoral and tibial influenced both contact pressure, i.e., SI = 0.57; SI = 0.65, and A-P ROM, i.e., SI = 0.58; SI = 0.6, respectively. However, posterior curvature of the femoral and tibial implants had a smaller impact on the contact pressure, i.e., SI = 0.31; SI = 0.23 and a higher impact on the I-E ROM, i.e., SI =0.72; SI = 0.58. It is noteworthy that in the frontal plane, frontal radius of the femoral implant impacted both contact pressure (SI = 0.38) and I-E ROM (SI = 0.35). Conclusion: Findings of this study highlighted how changes in the conformity of the femoral and tibial can impact the performance metrics.

Original languageEnglish
Pages (from-to)217-224
Number of pages8
JournalKnee
Volume22
Issue number3
DOIs
StatePublished - 1 Jun 2015

Keywords

  • Contact mechanics
  • Finite element simulation
  • Kinematics
  • Principal component analysis
  • Total knee arthroplasty

Fingerprint

Dive into the research topics of 'Contribution of geometric design parameters to knee implant performance: Conflicting impact of conformity on kinematics and contact mechanics'. Together they form a unique fingerprint.

Cite this