TY - JOUR
T1 - Comprehensive comparisons between frequency-domain analysis and time-domain analysis for LLC resonant converter
AU - Wei, Yuqi
AU - Luo, Quanming
AU - Mantooth, Alan
N1 - Publisher Copyright:
© 2020 The Institution of Engineering and Technology.
PY - 2020/7/24
Y1 - 2020/7/24
N2 - LLC resonant converter has been widely used in many applications due to its characteristics of high efficiency andhigh frequency characteristics. Analysis method plays great role in converter design and operation performance. For LLCresonant converter, the most frequently used analysis methods are frequency-domain analysis (FDA) and time-domain analysis(TDA). FDA assumes that only fundamental harmonics can deliver energy in the system, while TDA is obtained by solving circuitstate equations. In this study, comprehensive and complete comparisons between FDA and TDA in terms of analysismethodology, parameter design, analysis accuracy, conduction loss, other power losses, and system efficiency areimplemented. The analysis and comparison results show that under the same system specifications, by adopting TDA, a largermagnetising inductance value can be used when compared with FDA, which will reduce the resonant tank circulating currentand increase the system efficiency. The comprehensive analysis can provide guidance for engineers when analysing anddesigning LLC resonant converter. Finally, a 200 W experimental prototype was built and tested to verify the theoretical analysis.
AB - LLC resonant converter has been widely used in many applications due to its characteristics of high efficiency andhigh frequency characteristics. Analysis method plays great role in converter design and operation performance. For LLCresonant converter, the most frequently used analysis methods are frequency-domain analysis (FDA) and time-domain analysis(TDA). FDA assumes that only fundamental harmonics can deliver energy in the system, while TDA is obtained by solving circuitstate equations. In this study, comprehensive and complete comparisons between FDA and TDA in terms of analysismethodology, parameter design, analysis accuracy, conduction loss, other power losses, and system efficiency areimplemented. The analysis and comparison results show that under the same system specifications, by adopting TDA, a largermagnetising inductance value can be used when compared with FDA, which will reduce the resonant tank circulating currentand increase the system efficiency. The comprehensive analysis can provide guidance for engineers when analysing anddesigning LLC resonant converter. Finally, a 200 W experimental prototype was built and tested to verify the theoretical analysis.
UR - https://www.scopus.com/pages/publications/85088009798
U2 - 10.1049/iet-pel.2019.0831
DO - 10.1049/iet-pel.2019.0831
M3 - 文章
AN - SCOPUS:85088009798
SN - 1755-4535
VL - 13
SP - 1735
EP - 1745
JO - IET Power Electronics
JF - IET Power Electronics
IS - 9