Skip to main navigation Skip to search Skip to main content

Comparison of direct numerical simulation with volume-averaged method on composite phase change materials for thermal energy storage

  • Xiaohu Yang
  • , Qingsong Bai
  • , Zengxu Guo
  • , Zhaoyang Niu
  • , Chun Yang
  • , Liwen Jin
  • , Tian Jian Lu
  • , Jinyue Yan
  • KTH Royal Institute of Technology
  • Mälardalen University
  • Xi'an Jiaotong University
  • Nanyang Technological University
  • Nanjing University of Aeronautics and Astronautics

Research output: Contribution to journalArticlepeer-review

90 Scopus citations

Abstract

Melting heat transfer in open-cell metal foams embedded in phase-change materials (PCMS) predicted by the volume-averaged method (VAM) was systematically compared with that calculated using direct numerical simulation (DNS), with particular attention placed upon the contribution of natural convection in the melt region to overall phase change heat transfer. The two-temperature model based on the assumption of local thermal non-equilibrium was employed to account for the large difference of thermal conductivity between metallic ligaments and PCM (paraffin). The Forchheimer extended Darcy model was employed to describe the additional flow resistance induced by metal foam. For the DNS, a geometric model of metal foam based on tetrakaidehedron cells was reconstructed. The DNS results demonstrated significant temperature difference between ligament surface and PCM, thus confirming the feasibility of local thermal non-equilibrium employed in VAM simulations. Relative to the DNS results, the VAM combined with the two-temperature model could satisfactorily predict transient solid-liquid interface evolution and local temperature distribution, although pore-scale features of phase change were lost. The presence of natural convection affected significantly the melting front shape, temperature distribution and full melting. The contribution of natural convection to overall phase change heat transfer should be qualitatively and quantitatively given sufficient consideration from both macroscopic (VAM) and microscopic (DNS) point of views. Besides, practical significance and economic prospective using metal foam in TES unit for WHR system to provide residential heating or hot water is discussed and analyzed.

Original languageEnglish
Pages (from-to)700-714
Number of pages15
JournalApplied Energy
Volume229
DOIs
StatePublished - 1 Nov 2018

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • Direct numerical simulation
  • Natural convection
  • Open-cell metal foam
  • Phase change
  • Volume averaged method

Fingerprint

Dive into the research topics of 'Comparison of direct numerical simulation with volume-averaged method on composite phase change materials for thermal energy storage'. Together they form a unique fingerprint.

Cite this