Skip to main navigation Skip to search Skip to main content

Calibrating method of high voltage and current probe for fast pulse measurements

  • Dingguo Lai
  • , Yongmin Zhang
  • , Linshen Xie
  • , Weibo Yao
  • , Aici Qiu
  • , Jianjun Huang
  • , Shuqing Ren
  • , Li Yang
  • Northwest Institute of Nuclear Technology

Research output: Contribution to journalArticlepeer-review

11 Scopus citations

Abstract

A calibrating method of high voltage and current probe for fast pulse measurements is presented based on pulse formation principle. A voltage and current generator which used the output line and diode of Flash II accelerator as pulse formation line was built with a self-developed low inductance gas switch and load. A quasi-square waveform, with a rise time of about 3 ns and a half width of 20 ns, was measured when the voltage and current on the load are 0.75 kA and 13.5 kV, respectively. The voltage and current probes of diode of flash II accelerator were then calibrated, and their time responses were less than 4 ns. The calibrating method can generate a fast pulse for high voltage and current probe calibration in practical circumstance, it can also calibrate the probes of transmission-line pulse power devices.

Original languageEnglish
Pages (from-to)2469-2472
Number of pages4
JournalQiangjiguang Yu Lizishu/High Power Laser and Particle Beams
Volume22
Issue number10
DOIs
StatePublished - Oct 2010
Externally publishedYes

Keywords

  • B-dot
  • Differential capacitance divider
  • On-line calibration
  • Pulse formation principle
  • Quasi-square wave

Fingerprint

Dive into the research topics of 'Calibrating method of high voltage and current probe for fast pulse measurements'. Together they form a unique fingerprint.

Cite this