Skip to main navigation Skip to search Skip to main content

Calculation and experimental measure of leakage inductance of magnetic frequency tripler

  • Xi'an Jiaotong University

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

In this paper, an equivalent leakage reactance model of a magnetic frequency tripler is presented based on harmonics, which is analyzed by using the finite element method of harmonic balance. The results of digital simulation are consistent with experiment results and thus illustrate the correctness of the proposed method.

Original languageEnglish
Title of host publicationICEMS 2001 - Proceedings of the 5th International Conference on Electrical Machines and Systems
EditorsWang Fengxiang, Tang Renyuan
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages1113-1116
Number of pages4
ISBN (Electronic)7506251159, 9787506251150
DOIs
StatePublished - 2001
Event5th International Conference on Electrical Machines and Systems, ICEMS 2001 - Shenyang, China
Duration: 18 Aug 200120 Aug 2001

Publication series

NameICEMS 2001 - Proceedings of the 5th International Conference on Electrical Machines and Systems
Volume2

Conference

Conference5th International Conference on Electrical Machines and Systems, ICEMS 2001
Country/TerritoryChina
CityShenyang
Period18/08/0120/08/01

Keywords

  • finite element method of harmonic balance
  • leakage inductance
  • magnetic frequency tripler

Fingerprint

Dive into the research topics of 'Calculation and experimental measure of leakage inductance of magnetic frequency tripler'. Together they form a unique fingerprint.

Cite this