Skip to main navigation Skip to search Skip to main content

Bi-directional micropump based on temperature dependence of liquid viscosity

  • CFD Res. and Consult. Software GmbH

Research output: Contribution to journal › Article › peer-review

9 Scopus citations

Abstract

A micropump based on a novel flow rectification principle is developed. Instead of mechanical check valves, two fluid channels connected to a pump chamber are used for flow rectification, each of which has a narrow choke with an electric heater to change the flow resistance utilizing the temperature dependence of fluid viscosity. Net flow is generated by synchronizing the temperature change in the chokes to the actuation of the diaphragm on the bottom of the pump chamber. This method is suitable especially for miniaturized liquid handling systems because the flow behaviors in small size are viscosity dominant. Since the valve effect can be actively controlled through the signal patterns supplied to the heaters, flexible control of the pump function including bi-directional pumping is easily achieved. In order to have a high efficiency of rectification, it is important to create a large temperature difference localized at the choke of each valve channel. A prototype device actuated by a piezoelectric element was designed with the aids of FEM simulations, and fabricated employing the silicon based technologies. The pump function was successfully confirmed through experiments using the prototype device. It was shown that the volume flow rate was nearly proportional to the duration and the voltage of the heating pulse. This behavior agreed with the expected characteristic of the device with a strong damping effect caused by the very narrow gap at the chokes. The maximum volume flow rate achieved in the experiment was 5.5 μl/min.

Original languageEnglish
Pages (from-to)1-7
Number of pages7
JournalKikai Gijutsu Kenkyusho Shoho/Journal of Mechanical Engineering Laboratory
Volume53
Issue number6
StatePublished - Nov 1999

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Bi-directional micropump
  • Liquid viscosity
  • Temperature dependence
  • Valve-less pump

Fingerprint

Dive into the research topics of 'Bi-directional micropump based on temperature dependence of liquid viscosity'. Together they form a unique fingerprint.

Cite this