TY - JOUR
T1 - Benchmarking of the 3-D CAD-based Discrete Ordinates code "aTTILA" for dose rate calculations against experiments and Monte Carlo calculations
AU - Youssef, Mahmoud
AU - Feder, Russell
AU - Batistoni, Paola
AU - Fischer, Ulrich
AU - Jakhar, Shrichand
AU - Konno, Chikara
AU - Loughlin, Michael
AU - Villari, Rosaria
AU - Wu, Yican
PY - 2013/11
Y1 - 2013/11
N2 - Shutdown dose rate (SDDR) inside and around the diagnostics ports of ITER is performed at PPPL/UCLA using the 3-D, FEM, Discrete Ordinates code, ATTILA, along with its updated FORNAX transmutation/decay gamma library. Other ITER partners assess SDDR using codes based on the Monte Carlo (MC) approach (e.g. MCNP code) for transport calculation and the radioactivity inventory code FISPACT or other equivalent decay data libraries for dose rate assessment. To reveal the range of discrepancies in the results obtained by various analysts, an extensive experimental and calculation benchmarking effort has been undertaken to validate the capability of ATTILA for dose rate assessment. On the experimental validation front, the comparison was performed using the measured data from two SDDR experiments performed at the FNG facility, Italy. Comparison was made to the experimental data and to MC results obtained by other analysts. On the calculation validation front, the ATTILA's predictions were compared to other results at key locations inside a calculation benchmark whose configuration duplicates an upper diagnostics port plug (UPP) in ITER. Both serial and parallel version of ATTILA-7.1.0 are used in the PPPL/UCLA analysis performed with FENDL-2.1/FORNAX databases. In the FNG 1st experimental, it was shown that ATTILA's dose rates are largely over estimated (by ∼30-60%) with the ANSI/ANS-6.1.1 flux-to-dose factors whereas the ICRP-74 factors give better agreement (10-20%) with the experimental data and with the MC results at all cooling times. In the 2nd experiment, there is an under estimation in SDDR calculated by both MCNP and ATTILA based on ANSI/ANS-6.1.1 for cooling times up to ∼4 days after irradiation. Thereafter, an over estimation is observed (∼5-10% with MCNP and ∼10-15% with ATTILA). As for the calculation benchmark, the agreement is much better based on ICRP-74 1996 data. The divergence among all dose rate results at ∼11 days cooling time is no more than 15% among all participants.
AB - Shutdown dose rate (SDDR) inside and around the diagnostics ports of ITER is performed at PPPL/UCLA using the 3-D, FEM, Discrete Ordinates code, ATTILA, along with its updated FORNAX transmutation/decay gamma library. Other ITER partners assess SDDR using codes based on the Monte Carlo (MC) approach (e.g. MCNP code) for transport calculation and the radioactivity inventory code FISPACT or other equivalent decay data libraries for dose rate assessment. To reveal the range of discrepancies in the results obtained by various analysts, an extensive experimental and calculation benchmarking effort has been undertaken to validate the capability of ATTILA for dose rate assessment. On the experimental validation front, the comparison was performed using the measured data from two SDDR experiments performed at the FNG facility, Italy. Comparison was made to the experimental data and to MC results obtained by other analysts. On the calculation validation front, the ATTILA's predictions were compared to other results at key locations inside a calculation benchmark whose configuration duplicates an upper diagnostics port plug (UPP) in ITER. Both serial and parallel version of ATTILA-7.1.0 are used in the PPPL/UCLA analysis performed with FENDL-2.1/FORNAX databases. In the FNG 1st experimental, it was shown that ATTILA's dose rates are largely over estimated (by ∼30-60%) with the ANSI/ANS-6.1.1 flux-to-dose factors whereas the ICRP-74 factors give better agreement (10-20%) with the experimental data and with the MC results at all cooling times. In the 2nd experiment, there is an under estimation in SDDR calculated by both MCNP and ATTILA based on ANSI/ANS-6.1.1 for cooling times up to ∼4 days after irradiation. Thereafter, an over estimation is observed (∼5-10% with MCNP and ∼10-15% with ATTILA). As for the calculation benchmark, the agreement is much better based on ICRP-74 1996 data. The divergence among all dose rate results at ∼11 days cooling time is no more than 15% among all participants.
KW - 14-MeV integral experiments
KW - ATTILA 3-D Discrete Ordinates
KW - Calculation benchmarking
KW - FNG facility
KW - ITER diagnostics ports
KW - Shutdown dose rates
UR - https://www.scopus.com/pages/publications/84885955995
U2 - 10.1016/j.fusengdes.2013.07.010
DO - 10.1016/j.fusengdes.2013.07.010
M3 - 文章
AN - SCOPUS:84885955995
SN - 0920-3796
VL - 88
SP - 3033
EP - 3040
JO - Fusion Engineering and Design
JF - Fusion Engineering and Design
IS - 11
ER -