Abstract
Coupling of the Monte Carlo (MC) method and the discrete ordinate (SN) method is studied. An SN-MC coupling scheme is adopted in order to eliminate low sampling efficiency of the MC method and difficulty in complex geometrical modeling of the SN method. In the coupling method, the SN code provides neutron angular flux, and a coupling program is used to calculate probability distributions of surface sources. A modified source sampling subroutine is used to produce a combined surface source which contains bottom, top and side surfaces at the same time, and then a Monte Carlo calculation is performed. Preliminary numerical results demonstrate that the coupling method is correct and it can be used in pressurized water reactor cavity radiation streaming calculation.
| Original language | English |
|---|---|
| Pages (from-to) | 2946-2950 |
| Number of pages | 5 |
| Journal | Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams |
| Volume | 24 |
| Issue number | 12 |
| DOIs | |
| State | Published - Dec 2012 |
Keywords
- Combined surface source
- Coupling method
- Monte Carlo method
- Reactor cavity radiation streaming
- Source sampling subroutine
Fingerprint
Dive into the research topics of 'Application of Monte Carlo and discrete ordinate coupling method to pressurized water reactor cavity radiation streaming calculation'. Together they form a unique fingerprint.Cite this