Skip to main navigation Skip to search Skip to main content

Annular sub-Aperture stitching interferometry testing for large-caliber aspheric

  • Xi'an Jiaotong University

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

2 Scopus citations

Abstract

An annular sub-Aperture stitching interferometry testing is proposed for large-caliber aspheric lens testing, expanding the dynamic range of the interferometer, broadening the scope of the measurement, and reducing the cost of the measurement to a large extent without the use of compensating elements. The large-caliber aspheric is divided into several annular sub-Apertures, and there are some overlapping areas between each two adjacent sub-Apertures. When testing, the test aspheric is moved along the optical axis according to path planning so that the reference spherical shape and the test aspheric interest at points of common tangency to reduce the fringe density of the sub-Aperture. However, in the process of moving the test optic, six DOF (degrees of freedom) misalignment errors will occur. According to the rigid body kinematics theory, the misalignment error separation model is established so that the misalignment factors can be calculated by the information of each overlapping regions. Then all sub-Apertures are unified to the same reference with proper algorithm, and subsequently, misalignment error of the reference is removed by Zernike polynomial fitting, and the whole surface error is recovered. Simulation results are shown to demonstrate the feasibility of the method we developed. By analyzing the influence of the six DOF on the stitching result, the most important factor is obtained, and some measures are taken, that is, a measurement system combining two interferometers is designed, one of which is to measure the departures between the reference and the aspheric, and another to test the piston errors to be transmitted to the control system to improve the accuracy.

Original languageEnglish
Title of host publication8th International Symposium on Advanced Optical Manufacturing and Testing Technology
Subtitle of host publicationOptical Test, Measurement Technology, and Equipment
EditorsSandy To, Yudong Zhang, Ming Xu, Fan Wu
PublisherSPIE
ISBN (Electronic)9781628419191
DOIs
StatePublished - 2016
Event8th International Symposium on Advanced Optical Manufacturing and Testing Technology: Optical Test, Measurement Technology, and Equipment, AOMATT 2016 - Suzhou, China
Duration: 26 Apr 201629 Apr 2016

Publication series

NameProceedings of SPIE - The International Society for Optical Engineering
Volume9684
ISSN (Print)0277-786X
ISSN (Electronic)1996-756X

Conference

Conference8th International Symposium on Advanced Optical Manufacturing and Testing Technology: Optical Test, Measurement Technology, and Equipment, AOMATT 2016
Country/TerritoryChina
CitySuzhou
Period26/04/1629/04/16

Keywords

  • Annular sub-Aperture stitching
  • Least-squares fit
  • Misalignment
  • Zernike polynomial

Fingerprint

Dive into the research topics of 'Annular sub-Aperture stitching interferometry testing for large-caliber aspheric'. Together they form a unique fingerprint.

Cite this