TY - GEN
T1 - Annual operating characteristics of solar central water heater system assisted by heat pump
AU - Hu, Wei
AU - Gu, Zhaolin
AU - Feng, Shiyu
AU - Gao, Xiufeng
AU - Wang, Huiyu
AU - Luo, Cong
PY - 2007
Y1 - 2007
N2 - The solar central water heater (SCWH) could supply hot water for massive users effectively and reliably. A SCWH assisted by heat pump (SCWHP) was proposed by replacing the electrical heating appliance with the heat pump. The heat pump could grantee that SCWH woks under any conditions and energy consumption could be reduced sharply. Because the climate situation is quite different between the southern part and the northern part of China, annual operating property of SCWHP would be rather different placing the equipment in different regions. However, few studies f°Cus on this aspect. In the present paper, based on the meteorological data in Xi'an and Guangzhou city, 2005, a proper mathematical model calibrated by some experimental data was established to simulate the annual performance coefficient, input power of SCWHP respectively. Annual operating properties of the same apparatus placed in the two regions were also compared.
AB - The solar central water heater (SCWH) could supply hot water for massive users effectively and reliably. A SCWH assisted by heat pump (SCWHP) was proposed by replacing the electrical heating appliance with the heat pump. The heat pump could grantee that SCWH woks under any conditions and energy consumption could be reduced sharply. Because the climate situation is quite different between the southern part and the northern part of China, annual operating property of SCWHP would be rather different placing the equipment in different regions. However, few studies f°Cus on this aspect. In the present paper, based on the meteorological data in Xi'an and Guangzhou city, 2005, a proper mathematical model calibrated by some experimental data was established to simulate the annual performance coefficient, input power of SCWHP respectively. Annual operating properties of the same apparatus placed in the two regions were also compared.
UR - https://www.scopus.com/pages/publications/84875885618
M3 - 会议稿件
AN - SCOPUS:84875885618
SN - 9781622765447
T3 - ISES Solar World Congress 2007, ISES 2007
SP - 2027
EP - 2032
BT - ISES Solar World Congress 2007, ISES 2007
T2 - International Solar Energy Society Solar World Congress 2007, ISES 2007
Y2 - 18 September 2007 through 21 September 2007
ER -