Abstract
The performance of a parabolic G style radiant cooler under different conditions was computed by numerical method with the view angle of the radiant cooler as a variable parameter. It is found that the reduction of view angle significantly deteriorates the working performance of the radiant cooler. Although the inner heat exchange of a radiant cooler is very complicated, the cold stage temperature can be expressed as a linear function of the view angle in its variation range studied. A method is proposed to reduce the negative effect of the decrease in view angle. The major idea of the method is to change the temperature-controlling mode of the ambient housing. Numerical results show that the method is very effective.
| Original language | English |
|---|---|
| Pages (from-to) | 366-370 |
| Number of pages | 5 |
| Journal | Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics |
| Volume | 25 |
| Issue number | 3 |
| State | Published - May 2004 |
Keywords
- Radiant cooler
- View angle
- Working performance
Fingerprint
Dive into the research topics of 'Analysis of the view angle influencing on radiant cooler's working performance'. Together they form a unique fingerprint.Cite this