TY - GEN
T1 - Analysis of CHF characteristics of concentric-tube open thermosyphon by using artificial neural network
AU - Chen, Ronghua
AU - Su, Gunaghui
AU - Qiu, Suizheng
PY - 2010
Y1 - 2010
N2 - An artificial neural network (ANN) for predicting critical heat flux (CHF) of concentric-tube open thermosyphon has been trained successfully based on the experimental data from the literature. The dimensionless input parameters of the ANN are density ratio, ρl/ρv, the ratio of the heated tube length to the inner diameter of the outer tube L/Di, the ratio of frictional area, di/(Di + do), and the ratio of equivalent heated diameter to characteristic bubble size, D he/[σ/g(ρl-ρv)]0.5, the output is Kutateladze number, Ku. The predicted values of ANN are found to be in reasonable agreement with the actual values from the experiments with a mean relative error (MRE) of 8.46%. For a particular outer tube, the CHF increases initially and then decreases with increasing inner tube diameter, and has a maximum at an optimum diameter of inner tube (do,opt). The do,opt is correlated with the working fluid and may decrease with the increase of ρl/ρv. CHF decreases with the increase of L/Di, and the decreasing rate decreases as L/D i increases. In the influence scope of pressure, the CHF decreases with increasing pressure for R22, while increases with increasing pressure for R113.
AB - An artificial neural network (ANN) for predicting critical heat flux (CHF) of concentric-tube open thermosyphon has been trained successfully based on the experimental data from the literature. The dimensionless input parameters of the ANN are density ratio, ρl/ρv, the ratio of the heated tube length to the inner diameter of the outer tube L/Di, the ratio of frictional area, di/(Di + do), and the ratio of equivalent heated diameter to characteristic bubble size, D he/[σ/g(ρl-ρv)]0.5, the output is Kutateladze number, Ku. The predicted values of ANN are found to be in reasonable agreement with the actual values from the experiments with a mean relative error (MRE) of 8.46%. For a particular outer tube, the CHF increases initially and then decreases with increasing inner tube diameter, and has a maximum at an optimum diameter of inner tube (do,opt). The do,opt is correlated with the working fluid and may decrease with the increase of ρl/ρv. CHF decreases with the increase of L/Di, and the decreasing rate decreases as L/D i increases. In the influence scope of pressure, the CHF decreases with increasing pressure for R22, while increases with increasing pressure for R113.
UR - https://www.scopus.com/pages/publications/80055049168
U2 - 10.1115/ICONE18-29707
DO - 10.1115/ICONE18-29707
M3 - 会议稿件
AN - SCOPUS:80055049168
SN - 9780791849323
T3 - International Conference on Nuclear Engineering, Proceedings, ICONE
SP - 689
EP - 696
BT - 18th International Conference on Nuclear Engineering, ICONE18
T2 - 18th International Conference on Nuclear Engineering, ICONE18
Y2 - 17 May 2010 through 21 May 2010
ER -