Abstract
In the ADS blowdown phase during SBLOCAs in AP1000, ADS-4 valves open and vent directly to the containment. If a critical vapor velocity is reached in the two hot legs, the liquid phase can be entrained to the containment through the ADS-4 in the form of liquid droplet. In the present study, the RELAP5 code is modified with the entrainment correlations obtained from the ATLATS test facility which was constructed at OSU in USA. Furthermore, the characteristics of liquid entrainment through ADS-4 during a 5.08 cm (2 inch) cold leg SBLOCAs in AP1000 was investigated. Results showed that the current liquid entrainment model in RELAP5 underestimated the liquid entrainment quantity through ADS-4 and resulted in a non-conservative safety analysis results.
| Original language | English |
|---|---|
| Pages (from-to) | 178-183 |
| Number of pages | 6 |
| Journal | Hedongli Gongcheng/Nuclear Power Engineering |
| Volume | 36 |
| Issue number | 5 |
| DOIs | |
| State | Published - 15 Oct 2015 |
Keywords
- ADS-4
- AP1000
- Liquid entrainment
- RELAP5
- SBLOCA