Abstract
This paper presents an optical readout method based uncooled infrared imaging system that contains an optical read-out section and a bi-material micro-cantilever arrays (BMCA) detector. The optical read-out section is based on incoherent light spatial filter technique. The read-out section converts the deflection angles of BMCA caused by absorption of infrared (IR) radiation to a visible image through optical filtering operation of the BMCA with a knife-edge filter. A spatial mathematical model is presented to describe the read-out method and its validity is proved. The IR image of a person's hand obtained through the using of the 100∈×∈100 BMCA and the 12-bit A/D quantizer demonstrates the ability of the system to create image. The performance test shows that the average Noise-equivalent temperature difference (NETD) of the imaging system can arrive at about 183mK with some areas having a NETD as low as 78mK.
| Original language | English |
|---|---|
| Pages (from-to) | 261-271 |
| Number of pages | 11 |
| Journal | International Journal of Infrared and Millimeter Waves |
| Volume | 29 |
| Issue number | 3 |
| DOIs | |
| State | Published - Mar 2008 |
| Externally published | Yes |
Keywords
- IR
- Imaging
- Opto-mechanical
- Spatial filter
- Uncooled
Fingerprint
Dive into the research topics of 'An optical readout method based uncooled infrared imaging system'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver