An ICIM-CI Model Based IC EMS Evaluation Method for DSP IC in MMC-HVDC System

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

1 Scopus citations

Abstract

In this paper, the failure mechanism of DSP-based control circuits in high-voltage large-current modular multilevel converter (MMC) valve towers is studied. This study combines a low-voltage integrated circuit (IC) immunity model with a new perspective on electromagnetic interference (EMI) coupling effects. A new copper layer based coupling model of MMC valve tower combined with power system and digital control IC was established. By using the new model, the EMI introduced into the IC can be quantified. This advantage translates into a new DSP electromagnetic sensitivity (EMS) evaluation method that can be used as a guide for industrial applications.

Original languageEnglish
Title of host publicationEMC COMPO 2019 - 2019 12th International Workshop on the Electromagnetic Compatibility of Integrated Circuits
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages125-128
Number of pages4
ISBN (Electronic)9781728142616
DOIs
StatePublished - Oct 2019
Event12th International Workshop on the Electromagnetic Compatibility of Integrated Circuits, EMC COMPO 2019 - Haining, Hangzhou, China
Duration: 21 Oct 201923 Oct 2019

Publication series

NameEMC COMPO 2019 - 2019 12th International Workshop on the Electromagnetic Compatibility of Integrated Circuits

Conference

Conference12th International Workshop on the Electromagnetic Compatibility of Integrated Circuits, EMC COMPO 2019
Country/TerritoryChina
CityHaining, Hangzhou
Period21/10/1923/10/19

Keywords

  • DSP IC
  • EMI
  • EMS
  • MMC
  • failure mechanism
  • radiation
  • valve tower

Fingerprint