Skip to main navigation Skip to search Skip to main content

An experimental study of a novel integrated heat pipe-heat sink for chip cooling

  • Chang'an University
  • Xi'an Jiaotong University
  • Dalian Sunway Heat Transfer Technique Co. Ltd.

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

To increase thermal performance of a heat pipe-heat sink for chip cooling, a novel integrated heat pipe-heat sink is presented, whose condenser's fins outside cooling surface is about 0.38 m2. The time response, pressure drop and heat transfer characteristics of the integrated heat pipe-heat sink were investigated by experiment. Results show that the integrated heat pipe heat sink has high effective heat transfer performance. With the airflow velocity 2.93 m/s and maximum temperature difference restrict 50°C, the heat sink can dissipate 423 W and the corresponding thermal resistance is only 0.118 K/W, while the pressure drop through the heat sink is just 30 Pa.

Original languageEnglish
Pages (from-to)54-57
Number of pages4
JournalHuazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition)
Volume37
Issue number7
StatePublished - Jul 2009

Keywords

  • Chip cooling
  • Heat transfer characteristic
  • Integrated heat pipe-heat sink
  • Pressure drop characteristic
  • Time response characteristic

Fingerprint

Dive into the research topics of 'An experimental study of a novel integrated heat pipe-heat sink for chip cooling'. Together they form a unique fingerprint.