Skip to main navigation Skip to search Skip to main content

An experimental investigation on a novel high-performance integrated heat pipe-heat sink for high-flux chip cooling

  • Xi'an Jiaotong University
  • Dalian Sunway Heat Transfer Technique Co. Ltd.

Research output: Contribution to journalArticlepeer-review

33 Scopus citations

Abstract

The investigation of high-performance cooling device is highly desired. Heat pipe is a promising candidate to meet the thermal management challenges in the future. In the current investigation, a novel integrated heat pipe-heat sink is presented with a new design of condenser and wick structure. Experimental investigation on its thermal performance and pressure drop is conducted. For a total power of 420 W, the thermal resistance is 0.118 K/W and the maximum temperature difference reaches 50 K when the air flow rate is 71 m3/h (about 2.9 m/s frontal velocity) with pressure drop of 30 Pa.

Original languageEnglish
Pages (from-to)433-439
Number of pages7
JournalApplied Thermal Engineering
Volume28
Issue number5-6
DOIs
StatePublished - Apr 2008

Keywords

  • Experimental investigation
  • Integrated heat pipe-heat sink
  • Thermal performance
  • Wick structure

Fingerprint

Dive into the research topics of 'An experimental investigation on a novel high-performance integrated heat pipe-heat sink for high-flux chip cooling'. Together they form a unique fingerprint.

Cite this