Abstract
The investigation of high-performance cooling device is highly desired. Heat pipe is a promising candidate to meet the thermal management challenges in the future. In the current investigation, a novel integrated heat pipe-heat sink is presented with a new design of condenser and wick structure. Experimental investigation on its thermal performance and pressure drop is conducted. For a total power of 420 W, the thermal resistance is 0.118 K/W and the maximum temperature difference reaches 50 K when the air flow rate is 71 m3/h (about 2.9 m/s frontal velocity) with pressure drop of 30 Pa.
| Original language | English |
|---|---|
| Pages (from-to) | 433-439 |
| Number of pages | 7 |
| Journal | Applied Thermal Engineering |
| Volume | 28 |
| Issue number | 5-6 |
| DOIs | |
| State | Published - Apr 2008 |
Keywords
- Experimental investigation
- Integrated heat pipe-heat sink
- Thermal performance
- Wick structure
Fingerprint