@inproceedings{6a9fd723db0042ba9a05352d7c661110,
title = "An efficient approach for performance evaluation and parameter design of heat transfer enhancing structure",
abstract = "The effects of main geometrical parameters of the longitudinal vortex generator(LVG) called {"}common flow up{"} on heat transfer enhancement and pressure loss are numerically investigated. Taguchi method is used to guide the numerical simulations. Based on the results of the Taguchi method, a new fin with the combination of different vortex generators is proposed to substitute the original wavy fin-and-tube surface. The results show that the new fin with LVGs can save 9.08\% of pumping power while reaching the same amount of heat transfer rate as the wavy fin at inlet velocity of 2m/s, and it can also save 33\% of heat transfer area.",
author = "Zhou, \{Wen Jing\} and Fan, \{Ju Fang\} and Wu, \{Zhi Geng\} and He, \{Ya Ling\} and Tao, \{Wen Quan\}",
year = "2010",
doi = "10.1115/IHTC14-22100",
language = "英语",
isbn = "9780791849392",
series = "2010 14th International Heat Transfer Conference, IHTC 14",
pages = "199--206",
booktitle = "2010 14th International Heat Transfer Conference, IHTC 14",
note = "2010 14th International Heat Transfer Conference, IHTC 14 ; Conference date: 08-08-2010 Through 13-08-2010",
}