Skip to main navigation Skip to search Skip to main content

An automatic power decoupling control method on three level DC-AC converter to suppress the double-line-frequency ripple

  • Xi'an Jiaotong University

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › peer-review

2 Scopus citations

Abstract

In single phase DC-AC converter, power decoupling is always required due to the inherent double line frequency ripple caused by the instantaneous power unbalance between DC and AC side. The existing solutions include passive power decoupling and active power decoupling. Passive power decoupling scheme would apply a large electrolytic capacitor and consequently increase passive component requirement. Active power decoupling is to introduce a low power converter to compensate the ripple which inevitably increase the system cost and control complexity. To overcome these drawbacks, [1] proposed a novel double-line-frequency ripple suppression method based on three-level topology which redistributes the unbalanced power between two series connected capacitors and makes the capacitor voltage ripple complementary to each other. Thus the dc-link voltage ripple could be reduced to a large extent. However it is an open loop system, this paper proposed an automatic power decoupling control algorithm that can avoid the direct control of double line frequency ripple which reduces the amount of calculation. At the same time, it could achieve satisfied dynamic response and robust circuit operation. Theory analysis and experiment results will be explained in the following sections.

Original languageEnglish
Title of host publicationPEDG 2019 - 2019 IEEE 10th International Symposium on Power Electronics for Distributed Generation Systems
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages888-892
Number of pages5
ISBN (Electronic)9781728124551
DOIs
StatePublished - Jun 2019
Event10th IEEE International Symposium on Power Electronics for Distributed Generation Systems, PEDG 2019 - Xi'an, China
Duration: 3 Jun 2019 → 6 Jun 2019

Publication series

NamePEDG 2019 - 2019 IEEE 10th International Symposium on Power Electronics for Distributed Generation Systems

Conference

Conference10th IEEE International Symposium on Power Electronics for Distributed Generation Systems, PEDG 2019
Country/TerritoryChina
CityXi'an
Period3/06/19 → 6/06/19

Keywords

  • Automatic power decoupling
  • DC-AC
  • Double-line-frequency ripple
  • Single phase
  • Three-level

Fingerprint

Dive into the research topics of 'An automatic power decoupling control method on three level DC-AC converter to suppress the double-line-frequency ripple'. Together they form a unique fingerprint.

Cite this