Skip to main navigation Skip to search Skip to main content

Adaptive vibration control of hoop truss structure using voice coil actuator

  • Xi'an Jiaotong University

Research output: Contribution to journalArticlepeer-review

Abstract

The vibration of hoop truss structure can be attenuated effectively through the voice coil actuator (VCA) under an adaptive LMS-based feedback strategy. The governing equations of the hoop truss with voice coil actuator are obtained using finite element method. The LMS-based feedback control theory is introduced and a simulation on adaptive vibration control of hoop truss structure with voice coil is done under the LMS-based feedback control strategy. The results of the simulation indicate that adaptive LMS-based feedback control using VCA is a viable control mean.

Original languageEnglish
Pages (from-to)1359-1367
Number of pages9
JournalInternational Journal of Applied Electromagnetics and Mechanics
Volume52
Issue number3-4
DOIs
StatePublished - 2016

Keywords

  • hoop truss structure
  • LMS-based feedback control
  • Voice coil actuator

Fingerprint

Dive into the research topics of 'Adaptive vibration control of hoop truss structure using voice coil actuator'. Together they form a unique fingerprint.

Cite this