TY - JOUR
T1 - Aberration correction method based on double-helix point spread function
AU - Wang, Zhaojun
AU - Cai, Yanan
AU - Liang, Yansheng
AU - Dan, Dan
AU - Yao, Baoli
AU - Lei, Ming
N1 - Publisher Copyright:
© 2018 Society of Photo-Optical Instrumentation Engineers (SPIE).
PY - 2019/3/1
Y1 - 2019/3/1
N2 - Point spread function (PSF) engineering has met with lots of interest in various optical imaging techniques, including super-resolution microscopy, microparticle tracking, and extended depth-of-field microscopy. The intensity distributions of the modified PSFs often suffer from deteriorations caused by system aberrations, which greatly degrade the image contrast, resolution, or localization precision. We present an aberration correction method using a spiral-phase-based double-helix PSF as an aberration indicator, which is sensitive and quantitatively correlated to the spherical aberration, coma, and astigmatism. Superior to the routine iteration-based correction methods, the presented approach is iteration-free and the aberration coefficients can be directly calculated with the measured parameters, relieving the computing burden. The validity of the method is verified by both examining the intensity distribution of the conventional Gaussian PSF in three dimensions and observing muntjac skin fibroblast cells. This iteration-free correction method has a potential application in PSF engineering systems equipped with a spatial light modulator.
AB - Point spread function (PSF) engineering has met with lots of interest in various optical imaging techniques, including super-resolution microscopy, microparticle tracking, and extended depth-of-field microscopy. The intensity distributions of the modified PSFs often suffer from deteriorations caused by system aberrations, which greatly degrade the image contrast, resolution, or localization precision. We present an aberration correction method using a spiral-phase-based double-helix PSF as an aberration indicator, which is sensitive and quantitatively correlated to the spherical aberration, coma, and astigmatism. Superior to the routine iteration-based correction methods, the presented approach is iteration-free and the aberration coefficients can be directly calculated with the measured parameters, relieving the computing burden. The validity of the method is verified by both examining the intensity distribution of the conventional Gaussian PSF in three dimensions and observing muntjac skin fibroblast cells. This iteration-free correction method has a potential application in PSF engineering systems equipped with a spatial light modulator.
KW - aberration correction
KW - double-helix point spread function
KW - iteration-free
UR - https://www.scopus.com/pages/publications/85053185820
U2 - 10.1117/1.JBO.24.3.031005
DO - 10.1117/1.JBO.24.3.031005
M3 - 文章
C2 - 30182579
AN - SCOPUS:85053185820
SN - 1083-3668
VL - 24
JO - Journal of Biomedical Optics
JF - Journal of Biomedical Optics
IS - 3
M1 - 031005
ER -