Skip to main navigation Skip to search Skip to main content

A symbiotic skin hydrogel interface enabled by flexible hydrogel network with embedded enhancement structure

  • Jun Ma
  • , Mingxu Wang
  • , Yongfeng Wang
  • , Qian Wu
  • , Cunkai Zhou
  • , Yuchen Zhou
  • , Changlei Ge
  • , Jixiao Guo
  • , Feijun Zhao
  • , Mingming Hao
  • , Chonghui Fan
  • , Feng Wen
  • , Shuqi Wang
  • , Mengyuan Liu
  • , Yujie Liu
  • , Hao Shen
  • , Lianhui Li
  • , Ting Zhang
  • University of Science and Technology of China
  • CAS - Suzhou Institute of Nano-Tech and Nano-Bionics
  • The First Affiliated Hospital with Nanjing Medical University

Research output: Contribution to journal › Article › peer-review

1 Scopus citations

Abstract

Wearable electrophysiological monitoring based on hydrogel electrodes is pivotal for decoding the body’s “electrical language”, yet fundamentally hampered by the unstable mechano-electrical interface between flexible electrodes and the skin caused by dehydration and poor breathability. Here, we demonstrate a symbiotic interface between an embedded-interfacial enhanced breathable conductive hydrogel network (BCHN) and skin for high-fidelity long-term electrophysiological monitoring. By embedding sodium chloride-containing polyvinyl alcohol hydrogel into an oxidized electrospun 3D porous polylactic acid skeleton, a BCHN with embedded enhanced interface featuring dense ion transport pathways and multiple water molecule-adsorbing sites is constructed. Upon application, the breathable (1.85 kg·m⁻²·day⁻¹, ~3× skin perspiration) flexible conductive hydrogel network with bending stiffness of ~10−10N·m² seamlessly conforms to the microscopic landscape of the skin, forming a symbiotic BCHN-skin interface, which allows BCHN to “breathe” in harmony with the skin to preserve stable hydration and conductivity by dynamically balancing sweat capture, permeation, and evaporation, evidenced by a sustained 55 Ω impedance even at 20%RH. Integrated into a wearable monitoring system, the BCHN electrodes maintain high-quality signals (SNR > 25 dB) for over 30 days, thereby permitting the quantitative assessment and early warning of driver fatigue through long-term electroencephalography analysis.

Original languageEnglish
Article number8528
JournalNature Communications
Volume17
Issue number1
DOIs
StatePublished - Dec 2026
Externally publishedYes

Fingerprint

Dive into the research topics of 'A symbiotic skin hydrogel interface enabled by flexible hydrogel network with embedded enhancement structure'. Together they form a unique fingerprint.

Cite this