T1 - A study on performance characteristics of vapor injection heat pump cycle with indirect heat recovery
AU - Wei, Yuan
AU - Liu, Shuilong
AU - Yu, Jianlin
N1 - Publisher Copyright:
© 2022 Elsevier Ltd
PY - 2022/9/1
Y1 - 2022/9/1
N2 - This paper proposes a vapor injection heat pump cycle with indirect heat recovery, which adds a sub-cooler and an evaporator on the basis of conventional vapor injection heat pump cycle. In the added first sub-cooler, refrigerant exchanges heat with outdoor fresh air entrancing into indoor for improving the indoor air quality, which increases the temperature of the outdoor fresh air and the subcooling of refrigerant. In the added high-temperature evaporator, refrigerant absorbs the heat from indoor exhaust air through heat exchange, which can improve the heating capacity and the cycle performance. The refrigerant R32 is selected as the working fluid to analyze the performance of the cycle. The results show that under the same operating conditions, the volumetric heating capacity of the cycle is increased by 33%–72% and the coefficient of performance is improved by 20.5%–33.5% compared with the conventional sub-cooler vapor injection heat pump cycle. When the outdoor ambient temperature is lower, the improvement ratios of volumetric heating capacity and coefficient of performance is larger. Therefore, this novel cycle is suitable to be used at the lower ambient temperatures. In addition, the larger fresh air ratio can bring better cycle performance.
AB - This paper proposes a vapor injection heat pump cycle with indirect heat recovery, which adds a sub-cooler and an evaporator on the basis of conventional vapor injection heat pump cycle. In the added first sub-cooler, refrigerant exchanges heat with outdoor fresh air entrancing into indoor for improving the indoor air quality, which increases the temperature of the outdoor fresh air and the subcooling of refrigerant. In the added high-temperature evaporator, refrigerant absorbs the heat from indoor exhaust air through heat exchange, which can improve the heating capacity and the cycle performance. The refrigerant R32 is selected as the working fluid to analyze the performance of the cycle. The results show that under the same operating conditions, the volumetric heating capacity of the cycle is increased by 33%–72% and the coefficient of performance is improved by 20.5%–33.5% compared with the conventional sub-cooler vapor injection heat pump cycle. When the outdoor ambient temperature is lower, the improvement ratios of volumetric heating capacity and coefficient of performance is larger. Therefore, this novel cycle is suitable to be used at the lower ambient temperatures. In addition, the larger fresh air ratio can bring better cycle performance.
KW - Exhaust air
KW - Heat pump
KW - Indirect heat recovery
KW - Performance
KW - Vapor injection
UR - https://www.scopus.com/pages/publications/85135389467
U2 - 10.1016/j.tsep.2022.101437
DO - 10.1016/j.tsep.2022.101437
M3 - 文章
AN - SCOPUS:85135389467
SN - 2451-9049
VL - 34
JO - Thermal Science and Engineering Progress
JF - Thermal Science and Engineering Progress
M1 - 101437
ER -