A quasi-two-dimensional model for thermodynamic performance analysis of liquid hydrogen tank insulation system integrating vapor cooled shield with adiabatic para-ortho hydrogen conversion

  • Yakun Leng
  • , Shengqi Zhang
  • , Xinyang Wang
  • , Yuyang Wang
  • , Liang Pu
  • , Peng Xu
  • Xi'an Jiaotong University
  • Ltd.
  • Ltd.

Research output: Contribution to journalArticlepeer-review

Abstract

Hydrogen storage is a crucial technology for large-scale hydrogen deployment and faces substantial challenges associated with heat leakage. This study developed a quasi-two-dimensional model for liquid hydrogen tank insulation system integrating variable density multilayer insulation, spray-on foam insulation and vapor cooled shield. The adiabatic para-ortho hydrogen conversion were considered and the influence of single para-ortho hydrogen converter within single vapor cooled shield/double vapor cooled shields and double para-ortho hydrogen conversion converters within single vapor cooled shield were examined. Validation demonstrated that the quasi-two-dimensional model is more precise than the one-dimensional model. The optimal location of single para-ortho hydrogen conversion converter/double para-ortho hydrogen conversion converters and single vapor cooled shield/double vapor cooled shields were identified and the heat transfer mechanism in optimal insulation configurations with single vapor cooled shield/double vapor cooled shields were revealed for liquid hydrogen tank insulation system. The insulation performance of liquid hydrogen tank insulation system integrated with single vapor cooled shield improved by 3.85 % when the number of para-ortho hydrogen conversion converters exceeds two, while the improvement for liquid hydrogen tank insulation system integrated with double vapor cooled shields is only 0.38 %. Additionally, the influence of vapor cooled shield quantity becomes more significant as the warm boundary temperature increases. At 310 K, the impact of vapor cooled shield quantity on heat leakage is 6.70 % greater than that of single para-ortho hydrogen conversion converter in liquid hydrogen tank insulation system with single vapor cooled shield. In contrast, at 164 K, the impact is 1.70 % less pronounced.

Original languageEnglish
Article number138896
JournalEnergy
Volume339
DOIs
StatePublished - 1 Dec 2025

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • Adiabatic para-ortho hydrogen conversion
  • Liquid hydrogen
  • Multilayer insulation
  • Quasi-two-dimensional
  • Vapor cooled shield

Fingerprint

Dive into the research topics of 'A quasi-two-dimensional model for thermodynamic performance analysis of liquid hydrogen tank insulation system integrating vapor cooled shield with adiabatic para-ortho hydrogen conversion'. Together they form a unique fingerprint.

Cite this