TY - JOUR
T1 - A numerical study on the effect of roof windbreak structures in an air-cooled system
AU - Gu, Hongfang
AU - Zhe, Zhang
AU - Wang, Haijun
AU - Qi, Chen
N1 - Publisher Copyright:
© 2015 Elsevier Ltd. All rights reserved.
PY - 2015/8/12
Y1 - 2015/8/12
N2 - The ambient wind velocity seriously affects the heat transfer performance in a Direct Air-Cooled Condenser (DACC). The heat transfer rate of an upstream heat exchanger unit is lower than that in other heat exchanger units under unfavorable ambient winds. The current work uses Computational Fluid Dynamics (CFD) to numerically simulate and analyze the effect of roof windbreak system on the DACC in a 2 × 350 MW power station. The distortion of the air flow, and the hot air recirculation rate at the fan inlet surface were studied at different ambient wind velocities. Our results show that the vertical length L1, inclined length L2, and inclination angle α on the roof windbreak line screen affect the performance of the DACC significantly. The analysis further shows that the optimal performance of the DACC can be achieved under the structure size of L1 = 30 m, α = 60°, and L2 = 5 m. The air flow decreases at the no wind or low wind velocity due to setting of the windbreak line screen. Therefore, the height of the platform needs to be adjusted to meet the suction space requirement for the fan.
AB - The ambient wind velocity seriously affects the heat transfer performance in a Direct Air-Cooled Condenser (DACC). The heat transfer rate of an upstream heat exchanger unit is lower than that in other heat exchanger units under unfavorable ambient winds. The current work uses Computational Fluid Dynamics (CFD) to numerically simulate and analyze the effect of roof windbreak system on the DACC in a 2 × 350 MW power station. The distortion of the air flow, and the hot air recirculation rate at the fan inlet surface were studied at different ambient wind velocities. Our results show that the vertical length L1, inclined length L2, and inclination angle α on the roof windbreak line screen affect the performance of the DACC significantly. The analysis further shows that the optimal performance of the DACC can be achieved under the structure size of L1 = 30 m, α = 60°, and L2 = 5 m. The air flow decreases at the no wind or low wind velocity due to setting of the windbreak line screen. Therefore, the height of the platform needs to be adjusted to meet the suction space requirement for the fan.
KW - Ambient wind
KW - Direct air-cooled unit
KW - Numerical simulation
KW - Windbreak line screen
UR - https://www.scopus.com/pages/publications/84938890368
U2 - 10.1016/j.applthermaleng.2015.07.030
DO - 10.1016/j.applthermaleng.2015.07.030
M3 - 文章
AN - SCOPUS:84938890368
SN - 1359-4311
VL - 90
SP - 684
EP - 693
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
ER -