As the increase of switching frequency and the extensive use of planar transformers, the capacitive effects of transformers can't be neglected anymore. Firstly, several transformer parasitic capacitance models are introduced in this paper. Next, this paper proposes a novel experimental method, charge balance method, to measure transformer parasitic capacitances. This method is applicable to single lumped parasitic capacitance model. Finally, the step response method is performed to verify the charge balance method. Experimental results show that the charge balance method is of high accuracy.

Original languageEnglish
Title of host publicationICPE 2019 - ECCE Asia - 10th International Conference on Power Electronics - ECCE Asia
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages1565-1569
Number of pages5
ISBN (Electronic)9788957083130
StatePublished - May 2019
Externally publishedYes
Event10th International Conference on Power Electronics - ECCE Asia, ICPE 2019 - ECCE Asia - Busan, Korea, Republic of
Duration: 27 May 201930 May 2019

Publication series

NameICPE 2019 - ECCE Asia - 10th International Conference on Power Electronics - ECCE Asia

Conference

Conference10th International Conference on Power Electronics - ECCE Asia, ICPE 2019 - ECCE Asia
Country/TerritoryKorea, Republic of
CityBusan
Period27/05/1930/05/19

Keywords

  • Charge balance method
  • Measurement method
  • Step response method
  • Transformer parasitic capacitance