Abstract
The Boron-doped carbon nanotubes (BCNTs) modified glassy carbon (GC) electrode was obtained simply and used for highly selective and sensitive determination of dopamine (DA). Comparing with the bare GC and CNTs/GC electrodes, the BCNTs have higher catalytic activity toward the oxidation of DA and ascorbic acid (AA). Moreover, the voltammetric peaks of AA and DA were separated enough (ca. 238 mV) at the BCNTs/GC electrode, which is superior to that at the CNTs/GC electrode (ca. 122 mV). Thus, the selective determination of DA was carried out successfully in the presence of AA. A wide concentration range (2.0 × 10-8-7.5 × 10-5 M) and low detection limit (1.4 nM, S/N = 3) for the DA detection were obtained. The possibility of the BCNTs/GC electrode for the determination of DA in human blood serum has also been evaluated. The advantageous properties of this electrode for the DA determination lie in its excellent catalytic activity, selectivity and simplicity. The more edge plane sites presented on the BCNTs surface were partially responsible for its good analytical behavior.
| Original language | English |
|---|---|
| Pages (from-to) | 2091-2094 |
| Number of pages | 4 |
| Journal | Biosensors and Bioelectronics |
| Volume | 24 |
| Issue number | 7 |
| DOIs | |
| State | Published - 15 Mar 2009 |
| Externally published | Yes |
Keywords
- Ascorbic acid (AA)
- Boron-doped carbon nanotubes (BCNTs)
- Differential pulse voltammetry (DPV)
- Dopamine (DA)
Fingerprint
Dive into the research topics of 'A novel and simple strategy for selective and sensitive determination of dopamine based on the boron-doped carbon nanotubes modified electrode'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver