Abstract
In this paper, a mode stirrer composed of random positioned metal plates is proposed for reverberation chamber. The designing procedure of the mode stirrer is presented. The designed stirrer is compared with the common Z-shaped stirrer in both simulation and measurement. It is shown that in general the proposed stirrer outperforms the common Z-shaped stirrer with the same sweeping volume. Nevertheless, the measurement results show that the performance improvement of the designed stirrer becomes insignificant at higher frequencies with additional platform stirring. Albeit the difference, the stirring improvement of the designed stirrer is clearly demonstrated at low frequencies, which is more important due to the inherent low mode density at low frequency.
| Original language | English |
|---|---|
| Pages (from-to) | 1182-1188 |
| Number of pages | 7 |
| Journal | Applied Computational Electromagnetics Society Journal |
| Volume | 36 |
| Issue number | 9 |
| DOIs | |
| State | Published - Sep 2021 |