TY - GEN
T1 - A multi-resonant sliding-mode controller for single-phase grid-connected inverter with LCL-filter
AU - Liu, Weizeng
AU - Hao, Xiang
AU - Yang, Xu
AU - Zhao, Ming
AU - Liu, Tao
AU - Huang, Lang
PY - 2013
Y1 - 2013
N2 - Sliding mode control (SMC) is recognized as robust controller with a high stability in a wide range of operating conditions, however it suffers from chattering problem. In addition, the sliding surface that is a linear combination of the system state variables and the generated references would drift while the system parameters change or external disturbance exists, which affects the tracking error and THD of system output seriously. In this paper, a fixed switching frequency multi-resonant SMC (MRSMC) is proposed for single-phase grid-connected inverter. The chattering problem of SMC is eliminated by adopting Gao's reaching law and the parameters of SMC are optimized according to the ripple of the system output based on pulse width modulation (PWM). In order to fully eliminate the grid current tracking error and suppress its THD effectively, multiple resonant terms of the grid current error are added to the sliding function. Simulation and experimental results on a 5-kVA single-phase grid-connected inverter prototype show the effectiveness of the proposed control strategy.
AB - Sliding mode control (SMC) is recognized as robust controller with a high stability in a wide range of operating conditions, however it suffers from chattering problem. In addition, the sliding surface that is a linear combination of the system state variables and the generated references would drift while the system parameters change or external disturbance exists, which affects the tracking error and THD of system output seriously. In this paper, a fixed switching frequency multi-resonant SMC (MRSMC) is proposed for single-phase grid-connected inverter. The chattering problem of SMC is eliminated by adopting Gao's reaching law and the parameters of SMC are optimized according to the ripple of the system output based on pulse width modulation (PWM). In order to fully eliminate the grid current tracking error and suppress its THD effectively, multiple resonant terms of the grid current error are added to the sliding function. Simulation and experimental results on a 5-kVA single-phase grid-connected inverter prototype show the effectiveness of the proposed control strategy.
UR - https://www.scopus.com/pages/publications/84879326791
U2 - 10.1109/APEC.2013.6520653
DO - 10.1109/APEC.2013.6520653
M3 - 会议稿件
AN - SCOPUS:84879326791
SN - 9781467343541
T3 - Conference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC
SP - 2541
EP - 2546
BT - 2013 28th Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2013
T2 - 28th Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2013
Y2 - 17 March 2013 through 21 March 2013
ER -