Abstract
PWR cavity radiation streaming calculation is important for the evaluation of the radioactive dose rate in structural materials. Discrete Ordinates (S N) method has been widely used to solve shielding problems, but it is difficult to apply to a complex geometry. Monte Carlo (MC) method can treat the geometry exactly but requires very long computing time to obtain acceptable statistic deviations. Thus, an SN-MC coupling method is adopted in order to combine the advantages of both SN method and MC method in PWR cavity radiation streaming calculations. To develop this coupling method, two surface source models, the combined surface source model (CSSM) and the single surface source model (SSSM), are proposed and analyzed. From the numerical results two conclusions can be drawn. (1) The SN-MC coupling method offers a speedup factor of 2-20 compared with the MC method to obtain the same statistic deviations. (2) In the SN-MC coupling method, the CSSM is more efficient than the SSSM in reducing statistic deviations.
| Original language | English |
|---|---|
| Pages (from-to) | 162-171 |
| Number of pages | 10 |
| Journal | Annals of Nuclear Energy |
| Volume | 63 |
| DOIs | |
| State | Published - 2014 |
Keywords
- Cavity radiation streaming
- Combined surface source
- S-MC coupling
- Single surface source
- Source sampling
Fingerprint
Dive into the research topics of 'A deterministic and Monte Carlo coupling method for PWR cavity radiation streaming calculation'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver