Skip to main navigation Skip to search Skip to main content

A design strategy for long-term stability of porous PEEK implants by regulation of porous structure and in vivo mechanical stimulation

  • Yingjie Liu
  • , Ling Wang
  • , Jie Zhang
  • , Shuguang Liu
  • , Jibao Zheng
  • , Jianfeng Kang
  • , Enchun Dong
  • , Changning Sun
  • , Ruhan A
  • , Chaozong Liu
  • , Chuncheng Yang
  • , Dichen Li
  • Xi'an Jiaotong University
  • Southern Medical University
  • Central South University
  • Foshan University
  • Center for Medical Device Evaluation of NMPA
  • University College London
  • Ltd.

Research output: Contribution to journalArticlepeer-review

9 Scopus citations

Abstract

The bioinert nature of polyether ether ketone (PEEK) material limits the widespread clinical application of PEEK implants. Although the porous structure is considered to improve osseointegration of PEEK implants, it is hardly used due to its mechanical properties. This study investigated the combined influence of the porous structure and in vivo mechanical stimulation on implantation safety and bone growth based on finite element analysis of the biomechanical behavior of the implantation system. The combined control of pore size and screw preloads allows the porous PEEK implant to achieve good osseointegration while maintaining a relatively high safety level. A pore size of 600 µm and a preload of 0.05 N·m are the optimal combination for the long-term stability of the implant, with which the safety factor of the implant is >2, and the predicted percentage of effective bone growth area of the bone-implant interface reaches 97%. For further clinical application, PEEK implants were fabricated with fused filament fabrication (FFF) three-dimensional (3D) printing, and clinical outcomes demonstrated better bone repair efficacy and long-term stability of porous PEEK implants compared to solid PEEK implants. Moreover, good osteointegration performance of 3D-printed porous PEEK implants was observed, with an average bone volume fraction >40% three months after implantation. In conclusion, 3D-printed porous PEEK implants have great potential for clinical application, with validated implantation safety and good osseointegration.

Translated title of the contribution一种联合机械刺激调控促进多孔 PEEK 植入物骨整合的结构设计策略
Original languageEnglish
Pages (from-to)275-287
Number of pages13
JournalBio-Design and Manufacturing
Volume8
Issue number2
DOIs
StatePublished - Mar 2025

Keywords

  • Finite element analyses
  • Fused filament fabrication (FFF) 3D printing
  • Interface biomechanics
  • Maxillofacial implants
  • Osteointegration
  • Porous polyether ether ketone (PEEK) implant

Fingerprint

Dive into the research topics of 'A design strategy for long-term stability of porous PEEK implants by regulation of porous structure and in vivo mechanical stimulation'. Together they form a unique fingerprint.

Cite this