TY - GEN
T1 - A calibration method for conformal x-ray transmission imaging system
AU - Li, Yang
AU - Mou, Xuanqin
N1 - Publisher Copyright:
© COPYRIGHT SPIE. Downloading of the abstract is permitted for personal use only.
PY - 2021
Y1 - 2021
N2 - The X-ray source using ZnO nanowires as the cold cathode is first densely integrate a large number of X-ray sources into flat panel devices. Compared with traditional ray sources, X-ray sources device based on ZnO nanowires have small size, instantaneous response, and can be electronically controlled. We propose a new conformal transmission imaging system that uses this flat-panel ray source to irradiate objects with multiple points to complete extremely low-dose projection. In order to get the final image, it is necessary to process the original projection with an image restoration method to remove the projection aliasing caused by multiple point sources. Due to the addition of iteration in the image restoration process, the error caused by the geometric parameters will gradually become larger as the iteration progresses, resulting in distortion of the final image. Therefore, geometric correction of the imaging system is required. The new imaging system has a unique geometric relationship. Based on this geometric relationship, this paper proposes a geometric correction method applied to the new imaging scheme. In this method, the angle parameters in the new imaging system are estimated using a single point volume model. It only needs one projection of the phantom, and it can derive the analytical formula about the three angle errors, which can avoid falling into a local minimum. In this paper, we give the simulation results of the calibration method, which proves the validity and accuracy of the method.
AB - The X-ray source using ZnO nanowires as the cold cathode is first densely integrate a large number of X-ray sources into flat panel devices. Compared with traditional ray sources, X-ray sources device based on ZnO nanowires have small size, instantaneous response, and can be electronically controlled. We propose a new conformal transmission imaging system that uses this flat-panel ray source to irradiate objects with multiple points to complete extremely low-dose projection. In order to get the final image, it is necessary to process the original projection with an image restoration method to remove the projection aliasing caused by multiple point sources. Due to the addition of iteration in the image restoration process, the error caused by the geometric parameters will gradually become larger as the iteration progresses, resulting in distortion of the final image. Therefore, geometric correction of the imaging system is required. The new imaging system has a unique geometric relationship. Based on this geometric relationship, this paper proposes a geometric correction method applied to the new imaging scheme. In this method, the angle parameters in the new imaging system are estimated using a single point volume model. It only needs one projection of the phantom, and it can derive the analytical formula about the three angle errors, which can avoid falling into a local minimum. In this paper, we give the simulation results of the calibration method, which proves the validity and accuracy of the method.
KW - Conformal imaging
KW - Flat-panel sources.
KW - Geometric calibration
KW - Transmission imaging
UR - https://www.scopus.com/pages/publications/85103693595
U2 - 10.1117/12.2582284
DO - 10.1117/12.2582284
M3 - 会议稿件
AN - SCOPUS:85103693595
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Medical Imaging 2021
A2 - Bosmans, Hilde
A2 - Zhao, Wei
A2 - Yu, Lifeng
PB - SPIE
T2 - Medical Imaging 2021: Physics of Medical Imaging
Y2 - 15 February 2021 through 19 February 2021
ER -